Electric solution that empowers operators to predict, adapt, and act with confidence¡ªthroughout the life of the well
Find Tela workflows by discipline, technical task, and host application¡ªfrom data discovery and subsurface interpretation to drilling,
Modular data center infrastructure, prefabricated offsite and shipped ready to install¡ªcompressing deployment time by up to 40%
Our journey to lower emissions, decarbonizing customer operations, and scaling new energy systems.
We put people first by respecting human rights, building a more inclusive workplace, and driving positive socioeconomic outcomes.
We've identified three key areas that are significant for our operations: biodiversity, water, and circularity.
Explore the latest news, stories and perspectives from Ä¢¹½´«Ã½.
Step into energy's future with thought leaders from around the world.
Visit us at one of our upcoming tradeshows to speak directly to an expert.
Together, we create amazing technology that unlocks access to energy for the benefit of all.
Our planet needs balance to thrive, for the climate, for people, and for nature.
Published: 07/01/2009
Challenge: Determine the cumulative flow rate in 22 Solution: Used CleanPhase well test separator with SmartWeir phase separation technology as a standalone unit to efficiently separate fluids into three phases and measure each phase accurately Results: Measured a cumulative flow rate of 3,191 m³/d [20,068 bbl/d], which matched Sirte’s oil and condensate flow rate measurements and provided faster cleanup
Solution: Used CleanPhase well test separator with SmartWeir phase separation technology as a standalone unit to efficiently separate fluids into three phases and measure each phase accurately
Results: Measured a cumulative flow rate of 3,191 m³/d [20,068 bbl/d], which matched Sirte’s oil and condensate flow rate measurements and provided faster cleanup
Sirte Oil Company, operating under the National Oil Corporation of Libya, tested 22 Using a two-phase separator, a service company measured the total liquid flow rate and estimated the oil flow rate using the water cut, but it was unable to measure gas flow rates for some of the wells. The company¡¯s tests of the 22 wells indicated a total flow rate of 2,627 m?/d [16,520 bbl/d], which was more than 17% less than the measurements provided by Sirte¡¯s measuring facility.
Using a two-phase separator, a service company measured the total liquid flow rate and estimated the oil flow rate using the water cut, but it was unable to measure gas flow rates for some of the wells. The company¡¯s tests of the 22 wells indicated a total flow rate of 2,627 m?/d [16,520 bbl/d], which was more than 17% less than the measurements provided by Sirte¡¯s measuring facility.
Sirte called on Ä¢¹½´«Ã½ to verify the cumulative flow using CleanPhase flow rate measurement technology. The three-phase well test separator was used in a stand-alone configuration equipped with Coriolis meters and an electromagnetic meter. The Coriolis meters measure oil and gas mass flow rate rather than volumetric flow, so they are not affected by variances in fluid density, viscosity, pressure, or temperature. The electromagnetic meter monitors the water flow rate; its fullbore design prevents clogging by allowing greater solids volumes to pass through the CleanPhase separator during well cleanup.
With this setup, the system separated the fluids efficiently and measured each phase accurately. Furthermore, environmental risks were reduced because there was no need to dispose of unseparated fluids during cleanup periods. The system was fitted with SmartWeir technology, which accommodates fluctuating water flow rates and high water cuts, allows the oil/ water interface level and total liquid level to be adjusted, and enables the separator to be online even during the cleanup phase.
Separating the effluents into three phases and measuring them individually using the CleanPhase separator with Coriolis meters indicated a cumulative flow rate of 3,191 m³/d [20,068 bbl/d]—almost exactly the Sirte commingled During one of the well tests, the CleanPhase unit was rigged up in series with one of the Sirte conventional separators to allow a flow rate comparison. The rates measured by the two separators were found to be almost identical, but the CleanPhase separator provided the advantage of faster, more environmentally friendly cleanup operations. Sirte personnel opted for the CleanPhase unit for well testing and cleanup on other wells, and the conventional separator was demobilized.
During one of the well tests, the CleanPhase unit was rigged up in series with one of the Sirte conventional separators to allow a flow rate comparison. The rates measured by the two separators were found to be almost identical, but the CleanPhase separator provided the advantage of faster, more environmentally friendly cleanup operations.
Sirte personnel opted for the CleanPhase unit for well testing and cleanup on other wells, and the conventional separator was demobilized.
Unobtrusively monitor liquid levels and adjust the height of the weir to achieve true three-phase separation.